Clarke CDM20 Instrukcje Operacyjne Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 6
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
Resistance
Range Accuracy Resolution
±0.8% of rdg ± 3 digits
±0.8% of rdg ± 1 digit
0.1
1
10
100
1K
10K
100K
200
2K
20K
200K
2M
20M
200M
± 1% of rdg ± 2 digits
Overload Protection: 220V DC/RMS. AC on all ranges
Open Circuit Voltage: Lower than 700mV
±5% of rdg-10 dig ±10 dig
Thermocouple Temperature
- 20
O
C - 0
O
C ±5% of rdg ± 4 digits 1
O
C
0
O
C - 400
O
C ±1% of rdg ± 3 digits 1
O
C
400
O
C - 1000
O
C ±2% of rdg 1
O
C
Range Temp. Range Accuracy Res.
-20
O
C to
1000
O
C
Range Accuracy Resolution
20nF
200nF
2µF
20µF
±4% of rdg ± 3 digits
10µF
0.1nF
1nF
10nF
2nF
1µF
Capacitance
7
DC Current
AC Current
Overload Protection: 20mA/250V fuse
Frequency Range: 40Hz to 400Hz.
Max. Input Current: 10A
Indication: Average. (RMS of sine wave)
6
Overload Protection: 20mA/250V fuse
Max. Input Current: 10A
20mA
200mA
10A
±0.8% of rdg ± 1 digit
±1.5% of rdg ± 1 digit
10µA
0.1mA
10mA
±2% of rdg ± 5 digits
2mA
1µA
Range Accuracy Resolution
Range Accuracy Resolution
Range Accuracy Resolution
20kHz
10µA
Frequency
±1.5% of rdg ± 5 digits
Sensitivity: 200mV rms. Input, no more than 10V rms
20mA
200mA
10A
±1% of rdg ± 3 digits
±1.8% of rdg ± 3 digits
10µA
0.1mA
10mA
±3% of rdg ± 7 digits
Resistance
Range Accuracy Resolution
±0.8% of rdg ± 3 digits
±0.8% of rdg ± 1 digit
0.1
1
10
100
1K
10K
100K
200
2K
20K
200K
2M
20M
200M
± 1% of rdg ± 2 digits
Overload Protection: 220V DC/RMS. AC on all ranges
Open Circuit Voltage: Lower than 700mV
±5% of rdg-10 dig ±10 dig
Thermocouple Temperature
- 20
O
C - 0
O
C ±5% of rdg ± 4 digits 1
O
C
0
O
C - 400
O
C ±1% of rdg ± 3 digits 1
O
C
400
O
C - 1000
O
C ±2% of rdg 1
O
C
Range Temp. Range Accuracy Res.
-20
O
C to
1000
O
C
Range Accuracy Resolution
20nF
200nF
2µF
20µF
±4% of rdg ± 3 digits
10µF
0.1nF
1nF
10nF
2nF
1µF
Capacitance
7
DC Current
AC Current
Overload Protection: 20mA/250V fuse
Frequency Range: 40Hz to 400Hz.
Max. Input Current: 10A
Indication: Average. (RMS of sine wave)
6
Overload Protection: 20mA/250V fuse
Max. Input Current: 10A
20mA
200mA
10A
±0.8% of rdg ± 1 digit
±1.5% of rdg ± 1 digit
10µA
0.1mA
10mA
±2% of rdg ± 5 digits
2mA
1µA
Range Accuracy Resolution
Range Accuracy Resolution
Range Accuracy Resolution
20kHz
10µA
Frequency
±1.5% of rdg ± 5 digits
Sensitivity: 200mV rms. Input, no more than 10V rms
20mA
200mA
10A
±1% of rdg ± 3 digits
±1.8% of rdg ± 3 digits
10µA
0.1mA
10mA
±3% of rdg ± 7 digits
Przeglądanie stron 5
1 2 3 4 5 6

Komentarze do niniejszej Instrukcji

Brak uwag