MIG 220TE & 255TE
ELECTRICAL CONNECTIONS
WARNING! THIS APPLIANCE MUST BE EARTHED.
13
Connect the mains lead, through a suitably fused isolator switch, to a 230 Volt (50Hz)
electrical supply, having a fuse rating in accordance with that given in the specification
chart on page 2. A standard 13 Amp plug MUST NOT be used with this machine.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following
code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible lead of this appliance may not correspond with the
coloured markings identifying terminals in your electrical supply, proceed as follows:
Connect GREEN & YELLOW coloured cord to terminal marked with a letter
“E” or Earth symbol “ ” or coloured GREEN or GREEN & YELLOW.
Connect BROWN cord to terminal marked with a letter “L” or coloured RED.
Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK.
MIG 270TE
This model is designed for use with a 400V three-phase supply, and should be
connected through a suitably fused isolator switch.
The GREEN or GREEN & YELLOW wire should be connected to the EARTH terminal
or terminal marked with “ ” symbol. The other two wires are for connection to the
phase wires.
Cable Extensions:
IMPORTANT:
For extensions up to 10M, the size of the conductors MUST be at least the same size
as that used on the machine - 2.5mm
2
. It is NOT advised to use extensions greater
than this, but if it is absolutely necessary, the conductor size must be 4mm
2
up to a
maximum of 25M in length.
DANGER
NEVER OPERATE THIS MACHINE WITH THE SIDE PANELS PARTIALLY
OPENED OR COMPLETELY REMOVED
28
WIRING DIAGRAMS
MIG 220TE
Przeglądanie stron 12